Sizing charts, wiring schematics, and code summaries for your workday. Search by trade or save the references you use most. No account needed.

Favorites are saved in this browser. Source documents need an internet connection.

7 references

Electrical · Reviewed 2026-10-01

GFCI requirement finder

Common dwelling receptacles in bathrooms, kitchens, basements, laundry areas, garages, and outdoors generally need GFCI protection. Start with NEC 210.8(A), then confirm your locally adopted edition and any exceptions.

Scope: U.S. dwelling units only. Quick lookup for ordinary 120 V, 15 or 20 A general-use receptacles on single-phase circuits rated 150 V or less to ground. Local adoption, equipment rules, and exceptions can change the answer.

Common dwelling locations to check under NEC 210.8(A)
LocationQuick reference
BathroomGFCI generally required
KitchenIncludes receptacles beyond the countertop under the 2023 expansion
BasementIncludes finished and unfinished areas
Laundry areaGFCI generally required
GarageCheck the complete garage and accessory-building provision
OutdoorsCheck exceptions and separate equipment requirements
Conditions & source documents
  • Select the NEC edition adopted for the job, not simply the current calendar year. The 2026 NEC is not automatically in force everywhere.
  • This finder does not determine requirements for HVAC, EV charging, pools, appliances, commercial premises, or replacement work. Review the applicable sections and current NFPA amendments for those cases.
  • Record the location, circuit, adopted edition, and inspector guidance with the job before choosing equipment.

NFPA 70 — editions, free access, amendments, and errata ↗Schneider Electric — residential GFCI guide (August 2026) ↗Leviton — 2023 NEC kitchen expansion ↗Leviton — dwelling basements and receptacle scope ↗

Carpentry · Reviewed 2026-10-01

Floor joist span chart

Joist span depends on species, grade, size, spacing, and loads. This calculator compares your clear span with a published sleeping-area table for No. 2 lumber at 16-inch centers and a 30 psf live load.

Scope: Limited table lookup: residential sleeping areas, No. 2 lumber, 16 in on center, 30 psf live load, 10 or 20 psf dead load, and L/360 live-load deflection. Not for living areas, decks, roofs, engineered joists, or concentrated loads.

No. 2 joists at 16 in on center · 30 psf live / 10 psf dead load · L/360
Species2 × 62 × 82 × 102 × 12
Douglas Fir-Larch10 ft 9 in14 ft 1 in17 ft 2 in19 ft 11 in
Hem-Fir10 ft 0 in13 ft 2 in16 ft 10 in19 ft 8 in
Southern Pine10 ft 3 in13 ft 3 in15 ft 8 in18 ft 6 in
Spruce-Pine-Fir10 ft 3 in13 ft 6 in17 ft 2 in19 ft 11 in
Conditions & source documents
  • Measure clear span between support faces. The calculator compares your measurement with the table; it does not interpolate or extend the table to other spacing or loads.
  • Bearing, bracing, connections, holes, notches, member condition, and the building’s eligibility for prescriptive construction still need checking. A span comparison alone does not approve a structure.
  • For other grades, spacing, uses, or loads, use the complete AWC tables or obtain a project-specific structural design.

AWC / ICC — 2024 Code Conforming Wood Design, Figure 41, printed page 34 (PDF) ↗AWC — span calculator inputs and limitations ↗

Electrical · Reviewed 2026-10-01

Wire gauge reference

For ordinary applications under NEC 240.4(D), the general copper small-conductor overcurrent limits are 15 A for 14 AWG, 20 A for 12 AWG, and 30 A for 10 AWG. These limits are not a complete wire-sizing calculation.

Scope: 14–10 AWG copper only; 2023 NEC reference. General small-conductor protection limits, subject to specific code exceptions. Aluminum, cable assembly rules, correction factors, and load calculations are outside this lookup.

Copper small-conductor reference · NEC 240.4(D)
GaugeGeneral overcurrent limitApprox. solid conductor diameter
14 AWG15 A0.064 in
12 AWG20 A0.080 in
10 AWG30 A0.101 in
Conditions & source documents
  • A 75°C or 90°C ampacity column does not by itself allow a larger breaker for these small conductors.
  • Check load, continuous-load requirements, termination ratings, wiring method, ambient temperature, conductor grouping, voltage drop, and equipment instructions before choosing a conductor.
  • Diameter is bare solid copper, not the outside diameter of insulated cable. Do not use it to size conduit.

Southwire — XHHW-2 copper specifications and NEC 240.4(D) footnote ↗

Plumbing · Reviewed 2026-10-01

IPC drain slope chart

2021 IPC Table 704.1 sets minimum slopes of ¼ inch per foot for pipe 2½ inches or smaller, ⅛ inch per foot for 3–6 inches, and ¹⁄₁₆ inch per foot for 8 inches or larger. Upstream of a grease interceptor, use at least ¼ inch per foot.

Scope: 2021 International Plumbing Code, Section and Table 704.1. Horizontal drainage piping only. Confirm local adoption and amendments; this is not a UPC, storm drainage, or vent-sizing tool.

2021 IPC Table 704.1 · minimum horizontal drain slope
Nominal pipe sizeMinimum slopeApprox. slope
2½ in or smaller¼ in per ft2.08%
3–6 in⅛ in per ft1.04%
8 in or larger¹⁄₁₆ in per ft0.52%
Upstream of grease interceptor¼ in per ft (all sizes)2.08%
Conditions & source documents
  • Total fall in inches = horizontal run in feet × slope in inches per foot. A 20 ft run at ¼ in per ft needs 5 in of fall.
  • Measure horizontal run, not diagonal pipe length. Maintain a uniform slope; total fall alone does not establish that the installed pipe has no flat spots.
  • This checks slope arithmetic only. Pipe capacity, fixture units, venting, cleanouts, and available elevations require separate checks.

ICC — 2021 IPC Section 704.1 and Table 704.1 ↗

HVAC · Reviewed 2026-10-01

Trane error codes

Trane codes depend on the model and control board. This reference covers selected S9V2 faults from installer’s guide 18-CE01D1-1E-EN (2016), page 96. For example, E3.2 indicates an open first-stage pressure switch on that control.

Scope: Trane S9V2 models and control described in 18-CE01D1-1E-EN only. Match the unit label, board, and manual revision before using a code meaning. Other Trane furnaces, thermostats, and HVAC systems may use different codes.

Selected S9V2 fault codes · 18-CE01D1-1E-EN, page 96
CodeReported condition
E2.1Ignition retries exhausted; flame was not established.
E2.2Too many cycles with flame established and then lost.
E3.1First-stage pressure switch reported shorted.
E3.2First-stage pressure switch reported open.
E3.3Second-stage pressure switch reported shorted.
E3.4Second-stage pressure switch reported open.
E04An open limit circuit: thermal, rollout, or reverse-airflow switch.
E05Flame detected when it should be absent.
Conditions & source documents
  • Capture the model number, exact display, and symptoms for the service record. A fault identifies a reported condition; it does not prove that a particular part needs replacement.
  • Do not bypass pressure, rollout, or limit switches, or repeatedly reset a furnace to keep it running. Electrical, gas, and combustion diagnosis belongs with a qualified HVAC technician.
  • If you smell gas or a carbon monoxide alarm sounds, leave the building and contact emergency services or the gas utility from a safe location.

Trane — S9V2 installer’s guide 18-CE01D1-1E-EN, page 96 (PDF) ↗Trane — owner’s guides for other models ↗

Wiring diagrams · Reviewed 2026-10-04

GFCI single-receptacle connections

Supply connects to LINE; unused LOAD terminals remain covered.

Scope: Conceptual connections for Leviton GFNL2, instruction sheet PK-A3081-10-00-2B. Not physical terminal positions or a universal installation diagram.

Connection relationships · Connections, not terminal placement
Supply hot→LINE hot
Supply neutral→LINE neutral
Equipment ground→Device ground / box bonding as required
Conditions & source documents
  • Disconnect power and verify de-energization. Follow the complete device instructions and test procedure; refer unfamiliar circuits to a qualified electrician.
  • GFCI protection does not replace grounding or overcurrent protection.

Leviton GFNL2 installation instructions ↗

Wiring diagrams · Reviewed 2026-10-04

GFCI downstream connections

LINE receives the supply. Paired LOAD hot and neutral provide downstream protection.

Scope: Conceptual connections for Leviton GFNL2, instruction sheet PK-A3081-10-00-2B. Not physical terminal positions or a universal installation diagram.

Connection relationships · Connections, not terminal placement
Supply hot→LINE hot
Supply neutral→LINE neutral
Equipment ground→Device ground / box bonding as required
LOAD hot→Downstream hot
LOAD neutral→Downstream neutral
Conditions & source documents
  • Disconnect power and verify de-energization. Follow the complete device instructions and test procedure; refer unfamiliar circuits to a qualified electrician.
  • GFCI protection does not replace grounding or overcurrent protection.

Leviton GFNL2 installation instructions ↗

Use the source with the answer.

These U.S. references have specific editions, equipment models, and table conditions. Confirm local adoption, amendments, and manufacturer instructions. A quick lookup does not establish that a job is code compliant. The wiring diagrams show connection relationships for the named device, not a universal installation plan.